TC_J_09_CSMS — Sampled Meter Values - EventType Updated
TC_J_09_CSMS — Sampled Meter Values - EventType Updated
Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block J. MeterValues, page 439.
Identification
| Field | Value |
|---|---|
| Test case name | Sampled Meter Values - EventType Updated |
| Test case Id | TC_J_09_CSMS |
| Use case Id(s) | J02 |
| Requirement(s) | J02.FR.19 |
| System under test | CSMS |
| Functional block | J. MeterValues |
Description
The Charging Station samples the electrical meter or other sensor/transducer hardware to provide information about its Meter Values. Depending on configuration settings, the Charging Station will send Meter Values.
Purpose
To verify if the CSMS is able to handle a Charging Station sending sampled Meter Values, when there is an ongoing transaction.
Prerequisite(s)
N/a
Before (Preparations)
Configuration State:
- N/a
Memory State:
- N/a
Reusable State(s):
- State is EnergyTransferStarted
Main (Test scenario)
| Charging Station | CSMS |
|---|---|
| 1. The OCTT sends a TransactionEventRequest; With triggerReason is MeterValuePeriodic eventType is Updated timestamp <The intervals between the timestamps of the received Meter Value messages equals the configured sampled Meter Values interval>. sampledValue.context is Sample.Periodic; Note(s): _- This step will be executed every _<Configured sampled Meter Values interval>; - The OCTT will end the testcase after three MeterValues. | 2. The CSMS responds with a TransactionEventResponse |
Tool validations
N/a
Post scenario validations
- N/a