TC_B_43_CS — Set new NetworkConnectionProfile - Rejected
TC_B_43_CS — Set new NetworkConnectionProfile - Rejected
Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block B. Provisioning, page 65.
Identification
| Field | Value |
|---|---|
| Test case name | Set new NetworkConnectionProfile - Rejected |
| Test case Id | TC_B_43_CS |
| Use case Id(s) | B09 |
| Requirement(s) | B09.FR.02 |
| System under test | Charging Station |
| Functional block | B. Provisioning |
Description
The CSMS updates the connection details on the Charging Station. For instance in preparation of a migration to a new CSMS.
Purpose
To verify if the Charging Station is able to reject when the CSMS tries to set a network connection profile containing invalid data.
Prerequisite(s)
N/a
Before (Preparations)
Configuration State:
- N/a
Memory State:
- N/a
Reusable State(s):
- N/a
Main (Test scenario)
| Charging Station | CSMS |
|---|---|
| 2. The Charging Station responds with a SetNetworkProfileResponse | 1. The OCTT sends a SetNetworkProfileRequest with:; - configurationSlot is 999; - connectionData.messageTimeout <Configured messageTimeout>; - connectionData.ocppCsmsUrl <Configured ocppCsmsUrl>; - connectionData.ocppInterface <Configured ocppInterface>; - connectionData.ocppVersion OCPP20; - connectionData.securityProfile <Configured securityProfile> |
Tool validations
Step 2:
Message SetNetworkProfileResponse
- status Rejected
Post scenario validations
- N/a