TC_E_20_CSMS — Stop transaction options - EVDisconnected - EV side (able to charge IEC 61851-1 EV)
TC_E_20_CSMS — Stop transaction options - EVDisconnected - EV side (able to charge IEC 61851-1 EV)
Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block E. Transactions, page 384.
Identification
| Field | Value |
|---|---|
| Test case name | Stop transaction options - EVDisconnected - EV side (able to charge IEC 61851-1 EV) |
| Test case Id | TC_E_20_CSMS |
| Use case Id(s) | E06(S2), E10 |
| Requirement(s) | E06.FR.02 |
| System under test | CSMS |
| Functional block | E. Transactions |
Description
OCPP 2.x.x has a flexible transaction mechanism that allows the transaction start and stop points to be configured differently. This test covers one of the stop options.
Purpose
To verify if the CSMS is able to handle a Charging Station that stops a transaction when the EV and EVSE are disconnected at the EV side.
Prerequisite(s)
N/a
Before (Preparations)
Configuration State:
- N/a
Memory State:
- N/a
Reusable State(s):
- State is EnergyTransferSuspended
Main (Test scenario)
| Charging Station | CSMS |
|---|---|
| 1. Execute Reusable State EVDisconnected |
Tool validations
N/a
Post scenario validations
- N/a