TC_F_11_CSMS — Trigger message - MeterValues - Specific EVSE
TC_F_11_CSMS — Trigger message - MeterValues - Specific EVSE
Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block F. Remote Control, page 411.
Identification
| Field | Value |
|---|---|
| Test case name | Trigger message - MeterValues - Specific EVSE |
| Test case Id | TC_F_11_CSMS |
| Use case Id(s) | F06 |
| Requirement(s) | F06.FR.01,F06.FR.02 |
| System under test | CSMS |
| Functional block | F. Remote Control |
Description
The CSMS can request a Charging Station to send Charging Station-initiated messages. In the request the CSMS indicates which message it wishes to receive.
Purpose
To verify if the CSMS is able to trigger the Charging Station to send a MeterValuesRequest for a specific EVSE, using a TriggerMessageRequest.
Prerequisite(s)
N/a
Before (Preparations)
Configuration State:
- N/a
Memory State:
- N/a
Reusable State(s):
- N/a
Main (Test scenario)
| Charging Station | CSMS |
|---|---|
| 2. The OCTT responds with a TriggerMessageResponse; with status Accepted | 1. The CSMS sends a TriggerMessageRequest |
| 3. The OCTT sends a MeterValuesRequest; With evseId <Configured evseId> meterValue[0].sampledValue.context Trigger | 4. The CSMS responds with a MeterValuesResponse |
Tool validations
Step 1:
Message: TriggerMessageRequest
- requestedMessage must be MeterValues
- evse.id must be <Configured evseId>
Post scenario validations
- N/a