TC_G_03_CS — Change Availability EVSE - Operative to inoperative
TC_G_03_CS — Change Availability EVSE - Operative to inoperative
Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block G. Availability, page 199.
Identification
| Field | Value |
|---|---|
| Test case name | Change Availability EVSE - Operative to inoperative |
| Test case Id | TC_G_03_CS |
| Use case Id(s) | G03 |
| Requirement(s) | G03.FR.01, G03.FR.02, G03.FR.04, G03.FR.06 |
| System under test | Charging Station |
| Functional block | G. Availability |
Description
This test case covers how the CSMS requests the Charging Station to change the availability of one of the EVSEs from Operative to Inoperative. An EVSE is considered Operative in any status other than Faulted and Unavailable.
Purpose
To verify if the Charging Station is able to perform the change availability mechanism as described at the OCPP specification.
Prerequisite(s)
n/a
Before (Preparations)
Configuration State:
- N/a
Memory State:
- N/a
Reusable State(s):
- N/a
Main (Test scenario)
| Charging Station | CSMS |
|---|---|
| 1. Execute Reusable State Unavailable for <Configured evseId> |
Tool validations
N/a
Post scenario validations
- A message to report the state of a connector has been received for all connectors belonging to the specified EVSE.