TC_045_1_CSMS — Get Diagnostics
TC_045_1_CSMS — Get Diagnostics
Source: OCPP 1.6 — Compliancy Testing Tool — Test Case Document (Trial 2025-06, Draft). System Under Test: Central System, page 161.
Identification
| Field | Value |
|---|---|
| Test case name | Get Diagnostics |
| Test case Id | TC_045_1_CSMS |
| System under test | Central System |
Description
The Charge Point uploads a diagnostics log to a specified location based on a request of the Central System.
Purpose
The purpose of this test case it to check whether Central System can trigger the Charge Point to upload its diagnostics.
Prerequisite(s)
- N/a
Before (Preparations)
Configuration State(s):
- N/a
Memory State(s):
- N/a
Reusable State(s):
- N/a
Scenario Detail(s)
| Charge Point (SUT) | Central System (Tool) |
|---|---|
| 2. The Charge Point responds with a GetDiagnostics.conf to the Central System. | 1. The Central System sends a GetDiagnostics.req to the Charge Point. |
| [The Charge Point starts uploading the diagnostics log.]; 3. The Charge Point sends a DiagnosticsStatusNotification.req to the Central System. | 4. The Central responds with a DiagnosticsStatusNotification.conf to the Charge Point. |
| [The Charge Point has finished uploading the diagnostics log.]; 5. The Charge Point sends a DiagnosticsStatusNotification.req to the Central System. | 6. The Central responds with a DiagnosticsStatusNotification.conf to the Charge Point. |
Tool validation(s)
Charge Point side:
Step 3:
(Message: DiagnosticsStatusNotification.req) The status is Uploading
Step 5:
(Message: DiagnosticsStatusNotification.req) The status is Uploaded
Central System side:
- N/a
Expected result(s) / behaviour
Charge Point side:
The Charge Point has uploaded the diagnostics log to the location that was sent in step 1.
Central System side:
- N/a