TC_032_1_CSMS — Power failure boot charging point-configured to stop transaction(s)
TC_032_1_CSMS — Power failure boot charging point-configured to stop transaction(s)
Source: OCPP 1.6 — Compliancy Testing Tool — Test Case Document (Trial 2025-06, Draft). System Under Test: Central System, page 148.
Identification
| Field | Value |
|---|---|
| Test case name | Power failure boot charging point-configured to stop transaction(s) |
| Test case Id | TC_032_1_CSMS |
| System under test | Central System |
Description
This scenario is used to stop all transactions, when a power failure occurred.
Purpose
To test if the Central System can handle when a Charge Point stops all transactions, when a power failure occurred.
Prerequisite(s)
- N/a
Before (Preparations)
Configuration State(s):
- N/a
Memory State(s):
- N/a
Reusable State(s):
- Charging
Scenario Detail(s)
| Charge Point (SUT) | Central System (Tool) |
|---|---|
| [Disconnect and reconnect the power of the Charge Point.]; 1. The Charge Point sends a BootNotification.req | 2. The Central System responds with a BootNotification.conf |
| [Send per connector and connectorId = 0.]; 3. The Charge Point sends a StatusNotification.req | 4. The Central System responds with a StatusNotification.conf |
| 5. The Charge Point sends a StopTransaction.req | 6. The Central System responds with a StopTransaction.conf |
Tool validation(s)
Charge Point side:
Step 3:
(Message: StatusNotification.req) connectorId is <The connector which had the ongoing transaction> status is Finishing (Message: StatusNotification.req) The other StatusNotification messages. status is Available
Step 5:
(Message: StopTransaction.req) reason is PowerLoss
Central System side:
Step 2:
(Message: BootNotification.req) status is Accepted
Expected result(s) / behaviour
Charge Point side:
- N/a
Central System side:
- N/a