TC_004_2_CS — Regular Charging Session – Identification First - ConnectionTimeOut
TC_004_2_CS — Regular Charging Session – Identification First - ConnectionTimeOut
Source: OCPP 1.6 — Compliancy Testing Tool — Test Case Document (Trial 2025-06, Draft). System Under Test: Charge Point, page 10.
Identification
| Field | Value |
|---|---|
| Test case name | Regular Charging Session – Identification First - ConnectionTimeOut |
| Test case Id | TC_004_2_CS |
| System under test | Charge Point |
Description
This scenario is used to make a connector available when it is not used.
Purpose
To test if the Charge Point sets the connector back to Available, when the connectionTimeOut is reached.
Prerequisite(s)
- N/a
Before (Preparations)
Configuration State(s):
- Value for "ConnectionTimeOut" is <Configured connectionTimeout>.
Memory State(s):
- N/a
Reusable State(s):
- N/a
Scenario Detail(s)
| Charge Point (SUT) | Central System (Tool) |
|---|---|
| 1. Execute Reusable State Authorized | |
| [After the configured connectionTimeOut has expired.]; 2. The Charge Point sends a StatusNotification.req | 3. The Central System responds with a StatusNotification.conf |
Tool validation(s)
Charge Point side:
Step 2:
(Message: StatusNotification.req) status is Available
Central System side:
- N/a
Expected result(s) / behaviour
Charge Point side:
- N/a
Central System side:
- N/a