TC_041_CS — Fault Behavior
TC_041_CS — Fault Behavior
Source: OCPP 1.6 — Compliancy Testing Tool — Test Case Document (Trial 2025-06, Draft). System Under Test: Charge Point, page 55.
Identification
| Field | Value |
|---|---|
| Test case name | Fault Behavior |
| Test case Id | TC_041_CS |
| System under test | Charge Point |
Description
This scenario is used to refuse starting a transaction, when the Charge Point in fault state.
Purpose
To test if the Charge Point refuses starting a transaction, when it is in fault state.
Prerequisite(s)
- N/a
Before (Preparations)
Configuration State(s):
- N/a
Memory State(s):
- N/a
Reusable State(s):
- N/a
Scenario Detail(s)
| Charge Point (SUT) | Central System (Tool) |
|---|---|
| [Set the Charge Point in fault state.]; 1. The Charge Point sends a StatusNotification.req | 2. The Central System responds with a StatusNotification.conf |
| 3. [The EV Driver tries to start a transaction.]; [The Charge Point does not start a transaction.] |
Tool validation(s)
Charge Point side:
Step 1:
(Message: StatusNotification.req) status is Faulted
Step 3:
The tool waits for <Configured Transaction Duration> to verify that no transaction is started.
Central System side:
- N/a
Expected result(s) / behaviour
Charge Point side:
- N/a
Central System side: