TC_040_2_CS — Configuratoin key - Invalid value
TC_040_2_CS — Configuratoin key - Invalid value
Source: OCPP 1.6 — Compliancy Testing Tool — Test Case Document (Trial 2025-06, Draft). System Under Test: Charge Point, page 53.
Identification
| Field | Value |
|---|---|
| Test case name | Configuratoin key - Invalid value |
| Test case Id | TC_040_2_CS |
| System under test | Charge Point |
Description
This scenario is used to reject setting a configuration key, when an incorrect value is given.
Purpose
To test if the Charge Point is able to reject setting a configuration key, when an incorrect value is given.
Prerequisite(s)
- N/a
Before (Preparations)
Configuration State(s):
- N/a
Memory State(s):
- N/a
Reusable State(s):
- N/a
Scenario Detail(s)
| Charge Point (SUT) | Central System (Tool) |
|---|---|
| 2. The Charge Point responds with a ChangeConfiguration.conf OR; with a CallError. | 1. The Central System sends a ChangeConfiguration.req |
Tool validation(s)
Charge Point side:
Step 2:
(Message: ChangeConfiguration.conf) The status is Rejected OR (Message: CallError ErrorCode is PropertyConstraintViolation.
Central System side:
Step 1:
(Message: ChangeConfiguration.req) The key is MeterValueSampleInterval value is -1
Expected result(s) / behaviour
Charge Point side:
- N/a
Central System side:
- N/a